16-Chem-B12
Worked solutions to 2 past sittings (2017), 16 questions. Pick a sitting, or start from a topic below.
Topics across the sittings
Topics that come up in more than one sitting, taken from the headings of our worked solutions. A topic counts once per sitting.
- Anode-Bed Resistance (2 sittings): May 2017 Q3 · Undated paper Q3
- Dilute (2 sittings): May 2017 Q4 · Undated paper Q4
- Impressed-Current Cathodic Protection (2 sittings): May 2017 Q3 · Undated paper Q3
- Nernst Equation (2 sittings): May 2017 Q1 · Undated paper Q1
Questions by sitting
May 2017
- Question 1: Cu–Pb Galvanic Cell — Nernst Equation
- Question 2: Corrosion Rate of Iron from i corr
- Question 3: Impressed-Current Cathodic Protection — Anode-Bed Resistance
- Question 4: Dilute vs. Concentrated Sulfuric Acid in Steel Equipment
- Question 5: Cracked Brass-Lined HCl Cooler
- Question 6: Pump Material for Aerated 35% Sulfuric Acid
- Question 7: Lining for a Cracked 316 SS Phenol/Acid Digester
- Question 8: Inhibitor Selection for Cast-Iron Water Mains
Undated paper
- Question 1: Two-Metal Galvanic Cell — Nernst Equation
- Question 2: Corrosion Rate of Iron from i corr
- Question 3: Impressed-Current Cathodic Protection — Anode-Bed Resistance
- Question 4: Dilute vs. Concentrated Sulfuric Acid in Steel Equipment
- Question 5: Cracked Alloy-Lined HCl Cooler
- Question 6: Pump Material for 35% Sulfuric Acid with Ferric Sulfate
- Question 7: Lining for a Cracked 316 SS Phenol/Acid Digester
- Question 8: Inhibitor Selection for Cast-Iron Water Mains